pH/ORP Controllers Product Description
The
Global Water 6309POT multiparameter pH/ORP Controller
measures, analyzes, and controls pH, ORP and temperature
in one easy to use unit. The pH/ORP Controller's setup
and calibrations are done through a user-friendly menu
that may be password protected. Calibrations can be
performed quickly and accurately with automatic buffer
recognition of U.S. or European buffer sets, with the
values stored in the pH/ORP Controller's nonvolatile
memory. A large backlit display on the pH/ORP
Controllers provide pH, ORP, and temperature or pH, DO
and temperature measurements, plus the current mA output
and relay status.
The WQ250 multiparameter pH/ORP controllers provide
accurate on/off control via the five programmable relays
or the 4 to 20 mA output may be used for proportional
control. A standard RS-485 output allows for remote
access via PC compatible computer and makes it possible
to link multiple pH/ORP controllers to a common control
system. The pH/ORP controllers built-in temperature and
Automatic Temperature Compensation (ATC) functions may
be used with an ATC type sensor or with a 10K ohm
thermistor.
At power up, the WQ250 pH/ORP controllers perform a
self-diagnostic to ensure proper operation. pH/ORP
controllers electrode efficiency can be displayed to
indicate when electrode maintenance is necessary.
Housed in a watertight (IP65), ¼ DIN case, the 6309POT
pH/ORP controllers include a terminal block that
accommodates the tinned leads and spade lugs on
industrial type pH and ORP electrodes.
NOTES: A BNC to Y adapter is required to maintain the
IP65 rating when using sensors with a BNC connector. A
signal amplifier is required for sensor cable runs over
40 feet.
pH/ORP Controllers Specifications
pH/ORP Controllers:
|
Parameter: |
Range: |
Resolution: |
Accuracy: |
|
pH |
-2.00 to 16.00 pH |
0.01 pH |
±
0.01 pH ± 1 LSD |
|
ORP (absolute/relative) |
-2500 to 2500 mV / -3999 to 3999 mV |
1
mV / 1 mV |
±
0.2 % of span / ± 0.2 % of span |
|
Temp |
14 to 248 °F (-10.0 to 120.0 °C) |
32.18 °F (0.1 °C) |
±
32.18 °F (0.1 °C) |
pH:
Temp Compensation: Auto -10.0 to 120.0 °C
Buffer Recognition: 4.00, 4.01, 6.86, 7.00,
9.18, 10.01
Buffer Temperature Range: 0 to 60 °C
Electrode Offset Recognition: ± 100 mV at pH
7.00 - 91.7 to +108.3 at pH 6.86
Electrode Slope Recognition: ± 30 % at pH
4.00, 4.01, 9.18 or 10.01
Input Impedance: >1013 ohms
Calibration End Point Sensing: Yes
Temperature:
Temperature Sensor: Thermistor, 10.00 k ohm
at 77deg F (25 °C)
4-20 mA Analog Output:
Input Select: User selectable pH or ORP
Current Output Range: 4 to 20 mA (isolated),
programmable span
Current Output Scale: User programmable,
linear or log
Maximum Load: 500 ohm
Accuracy: ± 0.02 mA
Isolation Voltage: 500 V DC
Relays:
Control Type: 5 ON/OFF controls
Relay Output: 5 A at 115 V AC or 2.5 A at
220 VAC, resistive load only
Power Supply: 115 V AC or 230 V AC at 50/60 HZ
Communication: RS-485
Display: 128 x 64 graphical LCD with backlight
Ambient Temp. Range: 0 to 122 °F (0 to 50 °C)
Case: IP65, 1/4 DIN case, 148 mm depth
Dimensions: 3 5/8"W x 3 5/8"H x 5 7/8"D (96 x 96
x 148 mm)
Weight: 2.1 lb (950 g)
Certifications: CE, ISO 9001:2000
pH/ORP Controllers Options
6309POT pH/ORP Controller
Industrial pH/ORP Controller sensor not included.
|
|
|
|
pH & ORP
Controllers Electrodes: Flat Surface, Self-Cleaning
|
WQ220-020 pH/ATC Controller Electrode
20 FT w/Spade & Tinned Leads |
|
 |
WQ620-020 ORP Controller Electrode
20 FT w/Spade & Tinned Leads |
|
 |
|
pH & ORP
Controllers Accessories |
600B-Y Adapter
BNC Connector to Spade Lugs & Tinned Leads
|
|
 |
|
RELATED
PRODUCTS |
RE300
Handheld ORP Meter
Includes ORP electrode, sample cup with cap,
batteries, and 48” neckstrap. |
|
|
695ORP
Industrial ORP Transmitter
(ORP sensor not included) |
|
|
|
WQ600 ORP/Redux
Sensors |
|
|
|
WQ Water Quality
Sensors |
|