Global Water's Open
Channel Flow Monitor is reliable and accurate for measuring
and totalizing open channel flows for all flumes and weirs,
as well as for any gravity-type open-channel flow
application. The flow meter measures water depth with
Global Water's highly accurate
pressure transducer, and the unit's electronic circuitry
instantly calculates and displays water flow and totalizer
values for any depth-to-flow relationship in any engineering
units. The Open Channel Flow Monitor is easy to set up in
the field using a unique four-button programming system.
Open Channel Flows
For any open channel that is free flowing, there is a
specific relationship between depth of water and flow rate.
Whenever a given depth occurs, there will always be the same
flow. Therefore, if the flow rate is known for each depth,
a depth-to-flow relationship can be constructed. The Open
Channel Flow Monitor is pre-programmed with depth-to-flow
relationship tables. When the user digitally selects the
correct depth-to-flow relationship for an application, the
Open Channel Flow Monitor's LCD screen automatically
displays accurate flow rate measurements for any depth that
is reached. This water flow is averaged over time to
display total flow.
When using a primary device to measure flow, such as a
measuring flume or weir, there is a mathematical
relationship between depth and flow. When measuring flow in
a channel that does not have a primary device, the
depth-to-flow table can be constructed by measuring the flow
at several different depths, using Global Water's
Flow Probe.
Depth Measurement
Global Water's Open Channel Flow Monitor measures flow depth
with the highly-accurate
WL400 Water Level Sensor, which is a fully submersible
water level sensor constructed of stainless steel. The
standard level range is from 0 to 3' of water, which
provides for accurate flow measurements even with a depth
change as small as a fraction of an inch. The pressure
transducer is mounted slightly below the "zero" flow depth
of the channel, upstream from the throat of the flume or
weir. For open channels with no primary device, the sensor
is mounted below the lowest expected water depth. The water
level sensor has a 2-wire 4-20 mA signal, so the flow
computer can be mounted several hundred feet away, if
required. The sensor and computer can be connected with
standard, twisted-pair signal wire.
Global Water also offers an ultrasonic water level sensor
that allows the Open Channel Flow Monitor to measure
semi-solid flows or flows that are not suitable for a
standard submersible pressure transducer. Global Water
recommends that the ultrasonic sensor option only be used in
areas where AC power is available. You should strongly
consider using a submersible pressure transducer for
applications that are in areas without AC power.
Display and Outputs
The Open Channel Flow Monitor displays flow rate on a large
6-digit LCD screen. The totalized output is shown on a
second LCD display. The display reads in user-defined units
of flow, including mgd, csf, gpm, m3s.
The Flow Monitor also produces an analog 4-20 mA output
signal that is proportional to flow. This can be used for
chart recorders, dataloggers, or as an input to telemetry or
process control systems. In addition, the meter has a
flow-proportional output signal for triggering
water
samplers.
Digital Flow Computer
The Global Water Open Channel Flow Monitor has powerful
internal electronic circuitry that calculates and totalizes
flow. Desired engineering units and depth-flow
relationships (from over 20 pre-defined tables) can easily
be selected using the unit's four front panel push buttons.
User programming does not require the unit's enclosure to be
opened. The unit's manual includes programming information,
including depth-to-flow tables for all standard flumes and
weirs.
Enclosure
The enclosure is made of weatherproof injection molded
plastic. It is suitable for use in a wide variety of
environments. The enclosure can be wall-mounted and fitted
with conduit for sensor and power connections, if required.
Open Channel Flow Monitor Specifications
Rate Display: 6 digit + decimal place, LCD
Totalizer Display: 6 digit + decimal place, LCD
Accuracy: Pressure transducer: +0.2% FS + Flow
Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units
Enclosure: 4 3/4" W x 8" H x 3" D, NEMA 4X (IP67)
Power: 120 VAC to 240 VAC, optional: Battery powered
(Must be specified at time of ordering)
Current Draw: 50mA Typical, 16mA in sleep mode, and
120mA when the output relays are on
Pre-defined Tables
Parshall: 1", 2", 3", 6", 9", 12"
Palmer-Bowlus (4D): 4", 6", 8", 10", 12", 15"
Weir: 45° V notch, 90° V notch, 1' rectangular, 2'
rectangular
H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°
Custom Table
You must provide Global Water with a depth to flow equation
or look up table at time of order. Please allow for longer
lead times.
FC200 Open Channel Flow Monitor
0-3' Depth Sensor on 25' of cable included. Please
specify flume/weir type when placing order. |
|
|
FC200-U Open Channel Flow Monitor
0.17’ to 1.00’ ultrasonic sensor on 10' of cable
included (for use with AC power only). Please specify
flume/weir type when placing order. |
|
|
FC200-D Open Channel Flow Monitor Datalogging Option
0-3' Depth Sensor on 25' of cable included. Please
specify flume/weir type when placing order. Includes
internal GL500S-2-1 serial datalogger. |
|
|
FCBAT Battery Option
Includes Heavy-Duty Weather Resistant Environmental
Enclosure and 12V, 4.5Ah rechargable battery.
|
|
|
PDAGL500 Deluxe PDA Package
Handheld PDA download package for GL500. |
|
 |
|
RELATED
PRODUCTS |
FC200-S Sewer Flow Monitor
0-3' Depth Sensor on 25' of cable included. Please
specify correct sewer flow table when placing order.
|
|
|
FL16 Water Flow
Logger
The Water Flow Logger revolutionizes flow data
collection for applications such as inflow &
infiltration studies, stormwater and wastewater
collection systems, open channels and a host of other
gravity flow systems. |
|
|
Parshall flume
Industry standard rectangular flume used to monitor
streams and channels. |
|
|
Palmer-Bowlus Flume
U shaped channel flume specifically designed for
monitoring flows in pipes. |
|
|
H flume
Used to monitor free fall outflow from pipes or channels
when a Palmer-Bowlus or Parshall Flume will not work.
|
|
|
GL500 Open Channel Flow Recorder
Open channel flow recorder for sensor datalogging.
Includes Global Logger Software. With weather proof
enclosure and 12V battery. |
|
|
FSS-STD
Flow Sampling System
A unique combination of products that makes monitoring,
sampling, and recording stormwater or industrial
discharge water flows easy. |
|
|
WL700
Ultrasonic Water Level Sensor
Specify Water Level Range: 1', 3', 6'. Includes 10'
cable. |
|
|
FP101 Flow
Probe
Water velocity probe for determining open channel flow. |