Water Flow Loggers Product Description
The FL16, Water Level Logger, supports
USB cable interface for laptop and desktop data
downloading ...

...OR a
serial communication port for use with most
popular PDAs and telemetry solutions. |
Global Water’s FL16 Water Flow Logger revolutionizes
flow data collection for applications such as inflow &
infiltration studies, stormwater and wastewater
collection systems, open channels and a host of other
gravity flow systems. The FL16 Water Flow Loggers will
record over 81,000 depth, temperature, water flow and
velocity readings in sewer and drainage pipes, as well
as other open channel applications like flumes, weirs
and square channels. The specially engineered,
non-fouling water level sensor works in depths as little
as ½” and allows for deployment in manholes and other
difficult to access areas without the need to enter the
confined space.
The FL16 Water Flow Recorder's vented water flow
sensor is fully encapsulated with marinegrade epoxy.
The water flow sensor's electronics are encapsulated so
that moisture can never leak in through O-ring seals or
work its way into the vent tube and cause drift or
sensor failure, as is the case with many other vented
water flow sensors. The vent tube is sealed directly to
the wet-wet sensing element, and any moisture that may
enter the vent tube from the Water Flow Recorder's
housing will only contact the ceramic parts, not the
electronics.
FL16 Water Flow Recorder’s user-friendly
Windows-based software is tailored specifically for
calculating water flows in partially filled sewer and
drainage pipes using the Manning’s Equation, with
pull-down menus for selecting and entering the necessary
information. The Water Flow Recorder software has a
unique calibration feature which allows users to view
calculated water velocity, compare this to actual
measured data, and adjust the water flow parameters to
calibrate for the water flow conditions of a specific
application. Water flow equations for over 40 standard
flumes and weirs are provided, as well as user-definable
custom lookup tables which can be used to convert water
level to flow for virtually any application. Once
configured, all setup and water flow parameters are
stored in the Water Flow Recorder’s memory and are
uploaded to the software automatically upon connection.
This information can also be saved to a file for later
use, allowing Water Flow Recorders to be deployed in
multiple locations without the need to re-enter the
water flow parameters each time the Water Flow Recorders
are moved. The Water Flow Recorders operate on two
standard 9 volt batteries, which they monitor so you are
never caught off guard with dead batteries. A third
onboard lithium battery ensures your data will be safe
in the event you are unable to change the 9V batteries
before they fail. An optional protective housing
includes hardware for mounting the Water Flow Recorders
to a manhole step or other structure and also allows for
easy installation and replacement in the field.
Choose the FL16-U Water Flow Loggers for USB
interface – best for direct to PC or laptop
communication -- or the FL16-S Water Flow Logger serial
version, which is best for Windows CE or Mobile-based
PDA’s. NOTE: The Water Flow Loggers do NOT support
the Palm operating system. The FL16 Water Flow Logger package includes
the weather-resistant water flow logger unit,
non-fouling sensor with 25 feet of heavy duty cable and
FL16-ACM software package.
Water Flow Loggers Specifications
FL16 Water Flow Loggers
Memory: Non-volatile flash memory
Power: Two 9VDC Alkaline Batteries
Battery Life: Up to 1 year (depending on
recording intervals)
Resolution: 12 bit
Moisture Protection: Silicon coating (prevents
damage to electronics from condensation)
Temperature: -40° to +185°F (-40° to +85°C)
Humidity: 0-95% non-condensing
Storage Capacity: 81,759 time and date stamped
data points including battery voltage
Sample Modes: High Speed (10 samples per
second), Fixed Interval (Programmable from 1 sec to >1
year), Logarithmic, Exception
Data Overwrite: Select memory wrap or unwrap
(unwrap will stop logging data once memory is full)
Clock: Synchronizes to the time and date of
user's computer
Clock Accuracy: 0.0025% or 1 minute in 1 month
Clock Format: Month/Day/Year Hour/Minute/Second
Enclosure: 1 7/8" diameter x 11.5" length (fits
inside a 2" well), stainless steel UV protected PVC
vented for barometric pressure compensation
Weight: 1.6 lbs (with battery and 25' cable)
Communication Port:
FL16S: RS-232 4-pin circular connector
FL16U: USB Type B
Selectable Baud Rates:
9600,19200,28800,38400,57600,115200
Global Water Flow Loggers Software
Compatible with Microsoft's Windows 98, ME, 2000, NT,
and XP
Windows and Excel are trademarks of the Microsoft
Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
Water Flow Logger Vented Cable
Conductors: 4 each 22 AWG
Material: Marine grade polyurethane jacket, HD
polyethylene vent tube, full foil shield
Shield: Aluminum Mylar
Outside Diameter: 7.8mm (0.307”)
Length: Standard 25' (up to 500' from factory)
Temperature range: -30° to 85°C (-22 to 185°F)
Weight: ~65g/m (0.7 oz/ft)
Water Flow Sensor
Sensor Element: Silicone Diaphragm, Wet/Wet
Transducer
Level Range: 0-3'
Temperature Range: 32-122°F (0-50°C)
Linearity and Hysteresis: ±0.1% FS
Accuracy:
Level: ±0.1% FS at constant temperature,
±0.2% over 32° to 70°F range
Temperature: Smaller of 0.5°F or ±1% of
reading
Overpressure: 2 x full scale range
Burst Pressure: 10 x full scale range
Resolution: Infinite (Analog)
Output Currents:
Level: 4-20mA ±1mA of full scale
Temperature: 0-10mA ±1mA full scale
Supply Voltage: 10-36VDC
Current Draw: Combined level and temperature
output currents
Warm Up Time: 3 seconds recommended
Operating Temperature: 0° (not frozen) to +185°F
Compensated Temperature Range: 32° to 70°F
submerged, automatic barometric compensation Housing:
Material: 316 Stainless Steel Outer Sleeve,
PVC diffuser and strain relief
Size: 9” long x 1" diameter
Weight: ~250g (9oz)
Water Flow Recorder Software Information
The Water Flow Recorder includes Global Water Water
Flow Software, Windows-based software that provides many
useful features, such as real-time readout, measurement
interval and engineering unit selection, station ID
setting, and sensor calibration. The software makes
accessing stored data and setting options easy. Data
downloaded from the Water Flow Recorder can easily be
opened in any PC spreadsheet program for analysis and
graphic presentation. Globlal Water's Water Flow
Recorder Software will run on a PC-type laptop or
desktop computer running Windows 98 or later. To
communicate with the Water Flow Recorder, a computer
must be equipped with a communication port appropriate
to the type of water flow recorder you have, either a
standard RS232 serial or a USB host communication port.
Purchase of the Water Flow Recorder includes a RS232 or
USB cable (for communication between the water flow
recorder and your computer).
Water Flow Recorders Applications
Inflow and Infiltration, stream and river gauging,
Stormwater Flow Monitoring, Wastewater Flow
Calculations, Irrigation Canals, Weirs and Flumes, and
MUCH MORE...
Water Flow Recorders Options
FL16S Water Flow Logger
SERIAL version for collecting data with most PDAs.
The FL16 Water Flow Logger package includes
weather-resistant logger unit, non-fouling 0-3'
sensor with 25 feet of heavy duty cable and FL16-ACM
software package. |
|
|
F16U Water Flow Logger
USB version for collecting data with most
laptop/desktop computers. The FL16 Water Flow
Logger package includes weather-resistant logger
unit, non-fouling 0-3' sensor with 25 feet of heavy
duty cable and FL16-ACM software package.
|
|
|
WLEXC Extra Water Level Logger Cable
Cable length is measured from top of water level
recorder to bottom of sensor. WL16 includes 25 feet
of cable, and extra cable can be added up to 500
feet. |
|
|
PDAWL16 Deluxe PDA Package
Handheld PDA download package for WL16. |
|
|
FLMNT Protective Mounting Sleeve
2" capped PVC enclosure for easy mounting of Water
Flow Recorder. |
|
 |
|
RELATED
PRODUCTS |
FC200 Open Channel Flow Monitor
0-3' Depth Sensor on 25' of cable included.
Includes control outputs, flow, and totalizer
display for built in flume and weir tables.
|
|
|
FC200-S Sewer Flow Monitor
0-3' Depth Sensor on 25' of cable included.
Includes control outputs, flow, and totalizer
display for built in sewer pipe flow tables.
|
|
|
WL400
Water Level Sensor
When ordering, specify water level range that will
cover the maximum water level change for your
application (this is not necessarily the total depth
of water): 0-3', 0-15', 0-30', 0-60', 0-120',
0-250', 0-500'. Selecting the smallest water level
range possible will ensure the greatest accuracy.
Includes 25 feet of cable. |
|
|
WL430 Sewage Lift Station Wastewater Level Sensor
Includes 40' of cable |
|
|
WL700
Ultrasonic Water Level Sensor
Specify Water Level Range: 1', 3', 6'. Includes 10'
cable. |
|