Flow Sampling System Product Description
Global Water's Flow Sampling System is a unique water
monitoring package. This package includes an
easy-to-use lightweight composite water sampler, an open
channel flow monitor with dual displays and outputs, and
a data recorder that includes both Windows and PDA
software, allowing easy upload of data to a laptop,
desktop or PDA for transfer to spreadsheet programs.
NOTE: The Palm operating system is NOT supported. This
compact package is portable for field installation and
fully customizable to meet your monitoring needs.
Composite Water Sampler
Global Water's flow-proportional composite water sampler
is enclosed in a rugged, rainproof, lockable carrying
container. The composite water sampler includes a
2-gallon polyethylene wastewater sample bottle for
collecting composite samples, a peristaltic sampling
pump, a control panel (no programming required), and a
rechargeable gel cell battery. Also provided is a
sample pickup hose and a battery charger. Optional
additions include glass sample bottles, refrigerated
containers, portable ice containers and more.
Open Channel Flow Monitor
Global Water's FC200 Open Channel Flow Monitor is
reliable and accurate for measuring and totalizing open
channel flows for all flumes and weirs, as well as any
gravity-type open-channel flows. The flow monitor is
pre-programmed with over 20 different flume and weir
characteristics and can also be programmed for your
unique application. The unit measures water depth with
Global Water's highly accurate pressure transducer and
instantly calculates (for display and output) water flow
and totalizer values for any depth-to-flow relationship
in any engineering units. The Open Channel Flow Monitor
is easily set up in the field using a unique four-button
programming system.
Flow Data Recorder
Global Water's flow data recorder includes Windows-based
and PDA software, which provides many useful features,
such as real time monitoring, measurement interval and
engineering unit selections, station ID, and sensor
calibration. The Global Water Software makes accessing
stored data and setting options easy. The data recorder
monitors and logs both flow rate and total flow for your
records. Data downloaded from the recorder can easily
be opened in any PC spreadsheet program for analysis and
graphic presentation.
Flow Sampling System Specifications
Flow Sampling System Composite Water Sampler
Sample Size: 15 composite sample sizes from 50ml
to 2 liters plus a Full Bottle discrete setting
(Approximate sizes at 4 foot head)
Operating Temperature: 0° to +70°C
Materials:
Enclosure: Expanded UV protected PVC
Bottle: 2.5 gallon Polyethylene
Pickup Hose: 15' reinforced PVC 1/4" ID
polyethylene flexible tubing section with intake
strainer
Pump Tubing: Norprene 1/4" ID, 7/16” OD
Sample Pump:
Flow Rate: 1000 ml per minute at a 4 foot
head
Type: Peristaltic
Maximum Lift: ~20 feet
Battery: Rechargeable 5 AH Gel Cell
Battery Life: ~1 hour, continuous pumping under
load
Standby: 3 months while still retaining enough
power to run the pump to capacity
Flow Sampling System Open Channel Flow Monitor
Rate Display: 5 digit + decimal place, LCD
Totalizer Display: 6 digit, LCD (FSS-STD and
FSS-LTS only)
Accuracy: Pressure transducer: +0.2% FS, Flow
Monitor: +0.01% + the depth-flow-table error
Flow Units: CFS, GPM, m3s, MGD
Totalizer: Related to Flow Units (FSS-STD and
FSS-LTS only)
Relay Contacts: (All Models)
Voltage: 30VDC
Current: 5A/30VDC
Max Capacity: 150W
Relay 1, Pulse Output: NPN to Ground,
1.0Kohm pull-up resistor (connected to sampler) (WQS-STD
and WQS-LTS)
Relay 2, Pulse Output: NPN to Ground,
Open-collector (connected to datalogger and tied to
totalizer scaler) (WQS-STD and WQS-LTS)
Analog Output: 4mA minimum, 20mA maximum (Flow
reading)
Resolution: 0.005mA
Power:
FSS-STD and FSS-LTS: independent 12VDC
rechargeable battery
60mA DC normal, 100mA maximum
120uA during sleep mode
FSS-INT: uses the WS700 12VDC rechargeable battery
60mA DC normal, 100mA maximum
120uA during sleep mode
Pre-defined Tables
Parshall: 1", 2", 3", 6", 9", 12"
Palmer-Bowlus (4D): 4", 6", 8", 10", 12", 15"
Weir: 45° V notch, 90° V notch, 1' rectangular, 2'
rectangular
H: 0.4HS, 0.6HS, 0.5H, 0.75H, 1.0H, 1.5H, 2.0H
Trapezoidal: 60°
Custom Table
Equation or look up table provided at time of order.
Allow for longer lead times for custom table entry.
Flow Sampling System Datalogger
Memory: Non-volatile flash memory
Power:
FSS-STD and FSS-LTS: independent 12VDC rechargeable
battery
FSS-INT: uses the WS700 12VDC rechargeable battery
Standby Current: 70uA Typical
Logging Current: 5mA Typical + sensor current
Analog Sensor Inputs: 4-20mA
Resolution: 12-Bit, 4096 Steps
Sensor Warm-up Time: Programmable, 0-60 Sec
FSS-STD and FSS-INT: 6 Input channels + flow rate +
battery voltage monitor
FSS-LTS: 1 Input channels + flow rate + battery
voltage monitor
Digital Inputs:
Maximum Input Voltage: 24VDC
Maximum Frequency: 100Hz
Minimum Pulse Width: 2mS
Maximum Count: 65,535 (16-Bit)
FSS-STD and FSS-INT: Sample Event + total flow
FSS-LTS: 1 input channel connected to totalizer
Sample Now Input: Sample-on-Demand input, software
enabled (FSS-STD and FSS-INT only)
Maximum Input Voltage: 24VDC
Minimum Pulse Width: 2mS
Sample Modes:
Fixed Interval Programmable from 1 Sec. to >1 Year
High Speed 10 Samples per second
Logarithmic Sample Rate (Approximation)
Exception (Log only on deviation from previous
reading)
Storage Capacity:
FSS-STD and FSS-INT: 40,879 Recordings for all
inputs plus time
FSS-LTS: 81,759 Recordings for all inputs plus time
stamp
Data Overwrite: Select memory wrap or unwrap
(unwrap will stop logging data once memory is full)
Communication Ports:
FSS-STD and FSS-INT: RS-232 DB9 or USB Type B
FSS-LTS: RS-232 4-pin circular connector
Selectable Baud Rates: 9600, 19200, 28800, 38400,
57600, 115200
Clock: Synchronizes to the time and date of user's
computer
Operating Temperature: Industrial, -40ºC to +85ºC
(Battery may not apply)
Data Logger Software
Compatible with Microsoft's Windows 98, ME, 2000, NT,
and XP
Windows and Excel are trademarks of the Microsoft
Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
Mechanical:
FSS-STD: (2 enclosures)
Sampler Enclosure: 22”H X 17"W X 9"D
Flow Logger Enclosure: 14.5”Hx10”Wx6”D
Sampler Weight: 20lb
Flow Logger Weight: 14.1lb
FSS-LTS: (2 enclosures)
Sampler Enclosure: 22”H X 17"W X 9"D
Flow Logger Enclosure: 14.5”Hx10”Wx6”D
Sampler Weight: 20lb
Flow Logger Weight: 13.1lb
FSS-INT:
Enclosure: 22”H X 17"W X 9"D
Weight: 22lb
Flow Sampling System Options
FSS-STD Flow Sampling System
Includes flow-proportional WS700 composite water
sampler, FC200 open channel flow monitor, and
GL500-7-2 flow data recorder. |
|
|
FSS-LTS Flow Sampling System Lite
Includes flow-proportional WS700 composite water
sampler, FC200 open channel flow monitor, and
GL500S-2-1 flow data recorder integrated into open
channel flow monitor. |
|
|
FSS-INT Integrated Flow Sampling System
Includes flow-proportional WS700 composite water
sampler with built in open channel flow monitor and
GL500-7-2 flow data recorder. |
|
|
FSS Flow Sampling System with WS750 Water Sampler
Includes flow-proportional WS750 water sampler with
open channel flow monitor and GL500-7-2 flow data
recorder. |
|
|
PDAWL16 Deluxe PDA Package
Handheld PDA download package for WL16 or GL500.
|
|
 |
|
RELATED
PRODUCTS |
OxiTop® BOD Measurement Instrumentation
BOD measuring instrument for self-check with 6
measuring units, 115 VAC, 50/60 Hz power plug, and
accessories. |
|
|
WQS-STD Water Quality Sampling System
Includes triggered composite water sampler, process
controller, and data recorder. (NOTE: Water
quality sensor not included.) |
|