Circular Chart Recorders Product Description
The MRC 5000 is a digital circular chart recorder
capable of measuring, recording and controlling
(optional) up to two process variables from a variety of
inputs. Designed with the latest innovations in
recording technology, enclosures and functionality, the
digital circular chart recorders are slim, trim and
simple. Finding a place to install this digital
circular chart recorder is easy, with its compact panel
depth and short protrusion from the front panel. The
digital circular chart recorder's mode switch, located
next to the large red LED display, provides two
functions. When in the PROG/CAL/TEST position, the
digital circular chart recorder provides access to
program parameters, calibration facilities and test
functions. Digital circular chart recorder options are
matrix selectable and are shipped with default settings.
The versatile MRC 5000 digital circular chart
recorder accepts 4-20mA or 20-4mA inputs as well as mVDC,
VDC, thermocouple and RTD inputs. Changes in input type
are easily programmed in the digital circular chart
recorder in the field. With the digital circular chart
recorder's universal power supply (90–264VAC line
voltage at 50–60Hz), the MRC 5000 can be installed just
about anywhere.
Each MRC 5000 digital circular chart recorder ships
with a box of 100, 0-100/24 hour,10” charts.
Circular Chart Recorders Specifications
Functionality: Record only or high/low limit
and record/control, depending on model
Display: 4 digit; 0.56" high, red, 7-segment LED
w/3-button keypad
LED Indicators: four red alarm status; one green
pen 2 indicator
Chart: 10" circular chart
Chart Drive: DC Stepper Motor
Chart Rotation: User-configurable: 8, 12, 24 or
48 hrs or 7-days
Chart Range: Bottom and top of span –9999 to 9999
units
Pen Type: One or two disposable fiber tip pen(s)
Pen Color: Pen 1 (red); Pen 2 (green)
Memory Backup: Non-volatile EEPROM
Enclosure: Injection molded Noryl case; acrylic
window
Operating Temp: 32 to 122 °F (0 to 50 °C)
Storage Temp: –40 to 149 °F (–40 to 65 °C)
Control Outputs: SPDT relay, 5A resistive at
115VAC
Alarm Outputs: Process high or low; up to two
process alarms for each of two inputs
Inputs
DC Milliamps: 0–20mA; 4–20mA; internal
4.7ohm shunt resistor.
Thermocouple: J, K, T, R, S.
RTD: 100 ohm, platinum; 0.00385 ohms/ohm/°C
Volts: 0–10 VDC
DC Millivolts: 0–25mV, 0 to 50mV; 10–50mV,
0–5V and 1–5V
RTD Excitation: 150 microamps, typical
Isolation: Inputs are a common ground signal
Chart Accuracy: Recording: 0.5% of chart span
Chart Rotation: 0.5% of rotation time
Communications: RS-485 serial, MODBUS RTU
protocol
Approvals: CE, UL, CSA, FM, ISO 9002 registered
Dimensions: 14" (356mm)W x 14” (356mm)H x 3.8"
(97mm)D
Panel depth: 2.5" (64mm); panel protrusion: 1.3"
(33mm)
Weight: 15 lbs (6.8kg)
Circular Chart Recorders Options
51000015 Circular Chart Recorder
Circular chart recorder includes one pen input and
no relay outputs with a Nema 3 case. |
|
|
51100015 Circular Chart Recorder
Circular chart recorder includes two pen inputs and
no relay outputs with a Nema 3 case. |
|
|
51010015 Circular Chart Recorder
Circular chart recorder includes one pen inputs and
one relay outputs with a Nema 3 case. |
|
|
51120015 Circular Chart Recorder
Circular chart recorder includes two pen inputs and
two relay outputs with a Nema 3 case. |
|
|
|
Circular
Chart Recorder Pens |
CP410 Red Circular Chart Recorder Pen
Pen for input 1, 5 chart paper pens per pack.
|
|
|
CP411 Green Circular Chart Recorder Pen
Pen for input 2, 5 chart paper pens per pack.
|
|
|
|
Circular
Chart Recorder Chart Paper |
|
Model # |
Range |
Rotation Speed |
Per Pack |
|
CP001 |
0-100 |
24 Hr |
100 |
|
CP002 |
0-100 |
7 Day |
100 |
|
CP003 |
0-5 |
24 Hr |
100 |
|
CP004 |
0-5 |
7 Day |
100 |
|
CP005 |
0-10 |
24 Hr |
100 |
|
CP006 |
0-10 |
7 Day |
100 |
|
CP007 |
0-14 |
24 Hr |
100 |
|
CP008 |
0-14 |
7 Day |
100 |
|
|
NOTE: A
three box minimum order is required. |
|
Related
Products |
|
CR500
Circular Chart Recorder without Display
|
|
|
|
MRC7800 Flow Recorder/Controller with Display
|
|
|
|
VersaChart Circular Chart Recorders
|
|
|
GL500-2-1
Datalogger
Specify Serial or USB version when ordering.
Features 2 analog channels and 1 pulse channel.
Includes two internal 9V batteries, Windows-based
Global Water Datalogger Software, and PDA software
for the CE and Mobile operating systems. |
|
|
GL500-7-2
Multichannel Data Logger
Features 7 analog channels and 2 pulse channels, USB
and serial communication port, and includes software
and cables. Requires an external 12 VDC power
source. |
|
|
|
WQ Water Quality
Sensors |
|
|
|
CL500
Online Chlorine Analyzers |
|