Circular Chart Recorder Product Description
The
VersaChart™ Circular Chart Recorder is a truly versatile
and capable recorder/controller that can meet the
demands of virtually any chart recording application.
Outstanding Circular Chart Recorder Operation
The VersaChart Circular Chart Recorder prints brilliant
4 color trend lines, scales, and alphanumeric data on
12” plain paper charts, and at user-defined rotation
speeds from 6 to 9999 hours. The Circular Chart
Recorder prints all the time lines straight, rather than
curved, and they are printed on even time intervals for
improved readability and easy time determination. All
the trend lines are synchronized so there’s no drag pen
time offsets as in conventional multi-pen circular chart
recorders.
Excellent Circular Chart Recorder Features
The VersaChart Circular Chart Recorder features two
bright, easy to read, 40 character vacuum fluorescent
displays which can show values in a variety of user
configurable formats. The Circular Chart Recorder's
math and totalizer functions allow accurate flow
recording, and can be configured for open channel flow
systems that have standard flumes and weirs. The
VersaChart Circular Chart Recorder is also designed for
user-friendly operation with its quick-select keys, easy
to read display and easily replaced ink cartridge.
Circular Chart Recorder Versions to Meet Your
Needs
The VersaChart Circular Chart Recorders are available in
two versions; record only (with alarm outputs) and
recording controller. The Circular Chart Recorder is
capable of controlling any process from simple on/off to
dual 4-20mA outputs with full PID on up to 4 loops. We
have listed four different circular chart recorder
models below equipped with some of the most desirable
options. All our listed circular chart recorders
include NEMA 3 enclosure with glass window, transmitter
power supply for each input, a box of 100 12” charts
with 100 divisions and all necessary documentation.
Please call or email Global Water for other circular
chart recorder configurations to best meet your needs.
Circular Chart Recorder Specifications
Modes: Digital; record, controller or profile
functionality
Display: Two line, 40 character vacuum
fluorescent display with 0.21" (5mm) high characters; 15
keys for programming and unit operation; display modes;
automatic or manual sequencing; 3 display formats
Programmable Profiles: Up to 8 user programmable
profiles
Scan Rate: 2 scans/second; scan rate is
programmable for each input with the limitation that a
total of 16 measurements can be made in one second
Memory Backup: EEPROM and battery backed SRAM; 5
year minimum life
Status Indicators: 8 user-configurable red LED
status indicators; real time clock for time and date
stamping on chart output
Chart Paper: 10 to 12" circular chart; 100 charts
furnished with each instrument
Chart Drive: DC stepper motor
Chart Rotation: User-configurable from 6 to 9999
hours per revolution
Chart Range: Bottom and top of span –999999 to
999999 units
Pen Type: Disposable fiber tip pens
Pen Color: Pen 1 (red); Pen 2 (green); Pen 3
(blue); Pen 4 (black)
Chart Accuracy
Recording: 0.3% of span
Chart Rotation: ±0.2 minutes for a 24 hour
rotation, assuming all backlash removed, 6–9999 hours
Input Measurement Error: ±0.25% of measurement
span reference accuracy
Linearization Error:
TCs: ±0.25°C typical; ±0.5°C worst case with
exceptions
RTDs: ±0.1°C typical; ±0.3°C worst case
Ambient Temperature Error: 0.01% of span per
degree C deviation from 25°C
Cold Junction Compensation Error: ±0.2% @ 25°C
Cold Junction Compensation Rejection: 0 ±0.4°C
from 25°C
Noise Rejection
Normal mode: 100dB minimum at 60Hz or
greater
Common mode: 120dB minimum at 115VAC maximum
Power Consumption: 60VA max
Line Voltage: 90–264VAC 50/60Hz
Isolation: 500VDC/350VAC
Sensor Fault Detection: Sensor break on all
temperature controls, RTUs, 1 to 5 volt and 4–20mA
inputs
Transmitter Power Supply: Up to 4 isolated 25mA @
24VDC supplies available
Sensor Input Types:
Thermocouple: J, K, T, R, S, E, B, N, G, D,
C, Ni/Ni-Moly and Platinel II
RTD: 100 ohm, platinum 100 or nickel 100,1–2
wire; 0.00385 ohms or 0.00392/ohm/°C; –94° to 300°F
(–70° to 150°C)
RTD Excitation Current: 1mA
DC Voltage: 0 to 25mV, 0 to 100mV, 0 to 1V,
0 to 10V
DC Current: 0–20mA or 4–20mA
Control Outputs:
Relay: SPST; 5.0A resistive @ 115VAC; 2.5A
resistive, 1/8HP @ 230VAC
SSR Driver: Open collector output; short
circuit protected @ 100mA max; provides 4VDC @ 20mA or
3VDC @ 40mA
Current: 0–20mA or 4–20mA; 650 ohm maximum
load
Alarm/Event Outputs:
Number: Up to four alarms for each of four
process variables
Type: Process high/low and rate/rising and
falling
Relay: SPST/SPDT; 5.0A resistive @ 115VAC;
2.5A resistive @ 230VAC
SSR Driver: Open collector output; short
circuit protected @ 100mA max; provides 4VDC @ 20mA or
3VDC @ 40mA
Process Alarm: Direct (High) or Reverse
(Low) –999999 to 999999 units
Deviation Alarm: Direct (deviation above
setpoint) or Reverse (deviation below setpoint) –3000 to
3000 units
Deviation Band Alarm: Open or closed 1 to
3000 units
Communications
Port: RS-232/485 serial, half duplex
Protocol: Modbus RTU
Bit Rate: User-configurable 1200, 2400,
4800, 9600 baud
Address: User-configurable, 1–247
Construction/Enclosure: Gasketed, cover, case and
windows. Structural foam case and cover; optional door
lock or glass window option
Operating Temperature: 32° to 122°F (0° to 50°C)
Storage Temperature: -40° to 149°F (-40° to 65°C)
Ambient Temperature: 0.04% of span per degree C
deviation from 25°C
Humidity: 0% to 90% non–condensing R.H.
Vibration: 0.5 to 100Hz @ 0.2g
Protection: NEMA 3 standard; NEMA 4 optional
Mounting: Panel or wall
Weight: 25 lbs (9.1kg)
Dimensions: 14.12 x 7.75 x 16.77" (359 x 197 x
426mm)
Warranty: 2 Years
Ratings/Approvals
Safety: UL 1092 File E67237; CSA Spec 142
File 67237; CE EN60010-1 1193/1995
Immunity: CE compliance EN50082-2
Emissions: CE compliance EN550081-1:1992;
EN55022 Class A
Hazardous Location: ETL Listed Class 1 & II
Division 2 and Class III, Division 1 & 2 Ref 56042
Other: ISO 9002 registered
Circular Chart Recorder Options
|
Record
Only Circular Chart Recorders |
9111020110011 VersaChart Circular Chart Recorder
One pen, one input, one 4-20mA output, two relay
outputs, no math functions, and no totalizer.
|
|
|
9162020223011 VersaChart Circular Chart Recorder
Two pen, two input, two 4-20mA output, two relay
outputs, math functions, and totalizer. |
|
|
|
Record and
Control Circular Chart Recorders |
9211020110011 VersaChart Circular Chart Recorder
One pen, one input, one 4-20mA output, two relay
outputs, no math functions, and no totalizer.
|
|
|
9262040223011 VersaChart Circular Chart Recorder
Two pen, two input, two 4-20mA output, two relay
outputs, math functions, and totalizer. |
|
|
|
Circular
Chart Recorder Pens |
|
60500802 Green/Red Circular Chart Recorder Pen
Cartridge |
|
|
|
60500803 Blue/Green/Red Circular Chart Recorder
Pen Cartridge |
|
|
|
60500804 Blue/Green/Red/Black Circular Chart
Recorder Pen Cartridge |
|
|
|
Circular
Chart Recorder Chart Paper |
|
Model # |
Size |
Divisions (Rings) |
|
00215205 |
12" |
70 |
|
00215208 |
12" |
100 |
|
00215206 |
12" |
120 |
|
00215204 |
11" |
100 |
|
|
NOTE: A
three box minimum order is required. |
|
Related
Products |
|
CR500
Circular Chart Recorder without Display
|
|
|
|
MRC 5000
Circular Chart Recorder with Display |
|
|
|
MRC7800
Flow Recorder/Controller with Display
|
|
|
GL500-2-1
Datalogger
Specify Serial or USB version when ordering.
Features 2 analog channels and 1 pulse channel.
Includes two internal 9V batteries, Windows-based
Global Water Datalogger Software, and PDA software
for the CE and Mobile operating systems. |
|
|
GL500-7-2
Multichannel Data Logger
Features 7 analog channels and 2 pulse channels, USB
and serial communication port, and includes software
and cables. Requires an external 12 VDC power
source. |
|
|
|
WQ Water Quality
Sensors |
|