Magnetic Flow Meters Product Description
The
WMX101-Series flanged magnetic flow meters are the
perfect replacement for your old industrial mechanical
turbine or propeller flow meters. Because they have no
rotor to stop turning or bearings to wear out the WMX
industrial electromagnetic flowmeters are virtually
maintenance-free, especially in applications where
debris or sand would foul most industrial mechanical
flowmeters. WMX101-Series flanged magnetic flow meters
are also designed work with minimal straight pipe run
requirements, which is great when you have very little
space between the meter and an elbow.
The WMX101-Series flanged magnetic flow meters’
electronics are housed in a rugged NEMA 4X aluminum
enclosure with a 2-line LCD that clearly displays the
flow rate and totalizer. The WMX industrial
electromagnetic flowmeters have a solid state pulse
output that allows connection to a variety of devices
such as a FT420 remote display, PLC, telemetry system or
data logger. A pulse-to-analog converter can be added
if a 4-20 mA signal is needed from the magnetic
flowmeter. The WMX101 industrial electromagnetic
flowmeters are externally powered from a 12-24 VDC power
supply, and their low power requirements make them ideal
for solar powered applications. A shielded power/pulse
output cable with DIN connection is included with the
magnetic flow meter. The industrial electromagnetic
flowmeters' display housing is fitted with
tamper-evident features.
The display units of the standard WMX magnetic flow
meter models listed below are in US Gallons and cannot
be changed in the field. However, you may request one
of the following available flowmeter displays: Rate: MGD,
CFM, Liters/Minute; Total: Cubic Feet, Cubic Meters,
Megaliters.
Magnetic Flow Meters Applications
- Municipal water/wastewater
- Industrial water/wastewater
- Cooling tower water treatment
- Well usage reporting
Magnetic Flow Meters Specifications
Pipe Sizes: 4", 6", 8", 10"
Flow Range:
4" 12-500 GPM
6" 32-1200 GPM
8" 60-2200 GPM
10" 95-3500 GPM
Flanges: AWWA 150 lb. drilling
Pressure: 150 PSI working pressure
Temperature Range: 10º F to 130º F (-12º C to 55º
C)
Accuracy:
+1% at 100% to 10% of reading
+2% at 10% of reading to cut off
Materials:
Body: Welded steel, epoxy powder coated
Liner: HDPE
Electronics Housing: Die cast aluminum, powder
coated
Electrodes: 316 stainless steel
Rate Display: 6-digits in units of GPM
(standard), MGD, Liters/minute, CFM
Totalizer Display: 8-digits in units of Gallons x
1000, CU Feet, CU Meters, Megaliters
Power:
101: 12-24 VDC, 30 mA
104: 2 Lithium 3.6V “D” batteries, replaceable, 3
year life
Output Signal: Current sinking pulse, opto-isolated,
24 VDC, 10 mA max
Empty Pipe Detection: Hardware/software,
conductivity-based
Environmental: NEMA 4X standard, (optional
short-term immersible)
Dimensions/Weight:
|
METER SIZE |
L |
H |
T |
WEIGHT |
|
inch |
mm |
inch |
mm |
inch |
mm |
lbs |
kg |
|
4" |
9.84 |
250 |
7.4 |
188 |
0.625 |
15.9 |
21 |
9.5 |
|
6" |
11.81 |
300 |
8.5 |
216 |
0.688 |
17.5 |
36 |
16.3 |
|
8" |
13.78 |
352 |
9.5 |
241 |
0.688 |
17.5 |
50 |
22.7 |
|
10" |
17.72 |
450 |
10.4 |
264 |
0.688 |
17.5 |
75 |
34.1 |
Magnetic Flow Meters Options
WMX101-400 4" Magnetic Flow Meter
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX101-600 6" Magnetic Flow Meter
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX101-800 8" Magnetic Flow Meter
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX101-1000 10" Magnetic Flow Meter
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
|
Battery
Operated Magnetic Flow Meters |
WMX104-400 4" Magnetic Flow Meter, Battery
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX104-600 6" Magnetic Flow Meter, Battery
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX104-800 8" Magnetic Flow Meter, Battery
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
WMX104-1000 10" Magnetic Flow Meter, Battery
NOTE: The Magnetic Flow Meters listed above are in
units of US gallons and cannot be changed in the
field. Other display units such as MGD, CFM and
Liters/minute are available. Please specify rate
and totalizer display units when you order.
|
|
|
|
Optional
Magnetic Flow Meter Output Displays/Converters
|
FT420W Pulse to 4-20mA Output and Display
Wall mounted, 12-24VDC. NOTE: To use both the pulse
and 4-20mA outputs you will need the relay option.
|
|
 |
AO55W Blind 4-20ma Converter
Wall mounted. |
|
 |
|
Related
Products |
EX80 Series Fixed Depth Insertion Magmeter
Stainless Steel or PVC, for 1" to 8" size.
|
|
 |
EX100/200 Series Adjustable Depth Electromagnetic
Flow Sensor
Stainless Steel and Brass Insertion Electromagnetic
Flow Sensor, for 3" to 48" pipe diameter.
|
|
|
FM500 Ultrasonic Flow Meter
Transit time/Doppler flowmeter with datalogger & 10
FT cable. |
|
|
GL500 Turbine Insertion Flow Recorder
Turbine insertion flow recorder for flow recording.
Requires an external 12 VDC power source. With