|
Water Quality Monitoring System Product Description
Global Water’s WQMS Water Quality Monitoring System
allows you to monitor multiple water quality parameters
with a fully integrated, easy to use, economical
system. The standard Water Quality Monitoring System
includes our multichannel datalogger (featuring 7 analog
channels and 2 digital channels for data recording) and
four of our rugged 4-20 mA water quality sensors for
measuring water temperature, pH, conductivity, and
dissolved oxygen. To customize the Water Quality
Monitoring System for your application, you can select
up to three more analog sensors and up to two digital
sensors to monitor additional parameters such as
turbidity, ORP, water level, wind speed/direction,
rainfall, and more.
Smart Water Quality Data Recorder
The Water Quality Monitoring System’s water quality data
recorder features 7 analog channels, 2 pulse channels,
and USB and serial communication ports. The durable and
powerful datalogger is enclosed within a sturdy
weatherproof case. The Water Quality Monitoring
System's datalogger will operate for several months
before its internal 12VDC battery requires recharging.
Powerful PC and PDA Software
The WQMS Water Quality Monitoring System includes
Windows™-based Global Logger II software, which makes
accessing stored data and setting options easy. The
software provides many useful features, such as real
time readout, measurement interval and engineering unit
selection, station ID setting, and sensor calibration.
The WQMS Water Quality Monitoring System also includes
Windows™ CE based PDA software for simple data
collection in the field. Data downloaded from the
recorder can easily be opened in any PC spreadsheet
program for analysis and graphic presentation. NOTE:
The Palm operating system is NOT supported.
Rugged Water Quality Monitoring System Sensors
The WQMS Water Quality Monitoring System comes standard
with four rugged and reliable 4-20 mA water quality
sensors, including our water temperature sensor, pH
sensor, conductivity sensor (with a 0 to 5000µS range
standard), and dissolved oxygen sensor. Each sensor is
mounted on 25' of marine-grade cable, with lengths up to
500' available by special order. The sensors’
electronics are completely encapsulated in marine-grade
epoxy within a stainless steel housing. Each sensor
outputs a 4-20 mA signal.
Remote Communication Options
To add remote communication capabilities, select the
GL500-Mod Modem Package for telephone modem
communications (see Options) or the
RM100 for radio
communications. We also offer solar panels and a
battery charger to support your WQMS installation.
Customize for Your Application
To customize your WQMS, you can select up to three
additional analog sensors and two digital sensors from
Global Water’s line of rugged water quality, weather,
level, and flow sensors. Please see Options below and
the sensors in the water
quality and weather section of our catalog for
additional information. If you require a unique
water quality monitoring system to meet the needs of
your specific application, Global Water can work with
you to design a factory-integrated custom system.
Water Quality Monitoring System Specifications
Global Data Logger
Memory: Non-volatile flash memory
Power: Voltage: 7.2 VDC Min. to 24.0 VDC
Absolute Max
Standby Current: 70uA Typical
Logging Current: 5mA Typical + sensor current
Analog Sensor Inputs: 4-20mA (0-5VDC as factory
option)
Resolution: 12-Bit, 4096 Steps
Channels: 7 Input channels + battery voltage
monitor
Sensor Warm-up Time: Programmable, 0-15 Sec
Digital Inputs: 2 Independent pulse counters
Maximum Input Voltage: 24VDC
Maximum Frequency: 100Hz
Minimum Pulse Width: 2mS
Maximum Count: 65,535 (16-Bit)
Sample Now Input: Sample-on-Demand input,
software enabled
Maximum Input Voltage: 24VDC
Minimum Pulse Width: 2mS
Sample Modes: Fixed Interval Programmable from 1
Sec. to >1 Year
High Speed 10 Samples per second
Logarithmic Sample Rate (Approximation)
Exception (Log only on deviation from previous
reading)
Storage Capacity: 40,879 Recordings for all
inputs plus time stamp
Data Overwrite: Select memory wrap or unwrap
(unwrap will stop logging data once memory is full)
Communication Ports: RS-232 DB9 or USB Type B
Selectable Baud Rates: 9600, 19200, 28800, 38400,
57600, 115200
Clock: Synchronizes to the time and date of
user's computer
Operating Temperature: Industrial, -40ºC to +85ºC
(Battery may not apply)
Enclosure: Expanded UV protected PVC (5" x 2" x
3")
Weight: 1.5 lbs (with weather-proof enclosure)
Data Logger Software
Compatible with Microsoft's Windows 98, ME, 2000, NT,
and XP
Windows and Excel are trademarks of the Microsoft
Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
Weather-Proof Enclosure
Expanded UV protected PVC (9" x 7.5" x 4.5")
Battery: 12 Volt, 2.2 A/hr., Rechargeable (Gell Cell)
Weight: 3.5 lbs (with data logger)
Water Quality Monitoring System Temperature Sensor
Range: -50°C to +50°C
Accuracy: ±0.2°F or ±0.1°C
Maximum Pressure (Open Water): 200 psi
Operating Voltage: 10-36 VDC
Current Draw: Same as sensor output
Warm Up Time: 5 seconds minimum
Operating Temperature: -50° to +100°C
Size of Probe: 4-1/2" L x 3/4" Diameter
Weight: 8 ounces
Water Quality Monitoring System pH Sensor
Range: 0-14 pH
Accuracy: 2% of full scale
Maximum Pressure: 40 psi
Operating Voltage: 10-30 VDC
Current Draw: 5.5 mA plus sensor output
Warm Up Time: 3 seconds minimum
Operating Temperature: -5° to +55°C
Size of Probe: 10" L x 1-1/4" Diameter
Weight: 1 lb.
Water Quality Monitoring System Conductivity
Sensor
Range: 0-5,000, 0-10,000, 0-20,000 Micro Siemens
(micro mhos) per cm
Accuracy: 1% of full scale
Maximum Pressure: 50 psi
Operating Voltage: 12VDC (± 5%)
Current Draw: 0.8 mA plus Sensor output
Warm Up Time: 3 seconds minimum
Operating Temperature: -40° to +55°C
Size of Probe: 12" L x 1" Diameter
Weight: 8 ounces
Temperature Compensation: 2% per °C
Electrodes: 316 Stainless Steel
Water Quality Monitoring System DO Sensor
Range: 0-100% Saturation, 0-8 ppm, temperature
compensated to 25°C
Accuracy: ±0.5% of full scale
Maximum Pressure: 40 psi
Operating Voltage: 10-36 VDC
Current Draw: 15.5 mA plus sensor output
Warm Up Time: 10 seconds minimum
Operating Temperature: -40° to +55°C
Membrane: 0.001 FEP Teflon (standard)
Combined Error: 2% FS
Size of Probe: 11" L x 1-1/4" Diameter
Weight: 1 lb.
Water Quality Monitoring System Options
WQMS Water Quality Monitoring System
The standard unit includes a datalogger, temperature
sensor, pH sensor, conductivity sensor (with a
0-5000µS range unless otherwise specified), and DO
sensor. |
|
|
WQEXC Extra Cable
Standard sensors include 25' of cable, but can be
purchased with up to 500' of cable. |
|
|
|
Related
Products |
GL500-Mod Modem Package
Includes standard telephone modem and modem adapter
cable. |
|
|
|
RM100 Remote Radio Telemetry System
|
|
|
|
WQ710
Turbidity Sensor |
|
|
|
WQ600 ORP/Redux
Sensor |
|
|
WL400
Water Level Sensor
When ordering, specify water level range that will
cover the maximum water level change for your
application (this is not necessarily the total depth
of water): 0-3', 0-15', 0-30', 0-60', 0-120',
0-250', and 0-500'. NOTE: There is a $50 extra
charge for 0-500' range sensor. Selecting the
smallest water level range possible will ensure the
greatest accuracy. Includes 25 feet of cable.
|
|
|
|
RG200 Tipping Bucket Rain Gauge, 6"
|
|
|
|
RG600 Rain Gauge, 8" (Tipping Bucket)
|
|
|
SP101
Solar Panel (80mA)
Supplemental Power for remote data logger sites.
|
|
 |
SP102
Solar Panel (5 watts, 300mA minimum)
Supplemental Power for remote data logger sites.
|
|
 |
BC100
Smart Charger
Maintain constant battery level and increase battery
life. |
|
|
Deluxe PDA Package
Handheld PDA download package for GL500 Data
Logger. Standard PDA can read data from 22 full
data loggers before running out of memory. NOTE:
PDAs WILL NOT INTERFACE WITH GLOBAL WATER
DATALOGGERS WITHOUT A CUSTOM SERIAL CABLE (Serial
cable is included with this package.) |
|
 |
|