Water Quality Sampler System Product Description
Global Water has created a unique water quality sampling
system. This system includes an easy to use lightweight
triggered composite water sampler, a water quality
process controller with dual relay outputs, and a data
recorder that is MS Windows compatible. The compact
water quality sampler system is portable for field
installation and fully customizable to meet your needs.
Water Quality Sampler System Controller
The Water Quality Sampler System Controller’s LCD
display shows the type of sensor that is being
monitored, the data reading and the engineering units.
The display also indicates if either relay has been
triggered since last reset, which relay was triggered,
and whether the maximum or minimum limit was exceeded.
Two separate relays are provided, one triggering the
Water Quality Sampler System Sampler and the other for
controlling all types of external devices including
alarms, mixers, pumps, control valves, floodgates and
telemetry systems. Each relay is independently
programmable to trigger on maximum and/or minimum levels
in one of three different modes.
Water Quality Sampler System Sampler
Global Water triggered Water Quality Sampler System
Samplers are enclosed in rugged, rainproof, lockable
carrying containers. Inside each standard water quality
sampler container is a 2-gallon polyethylene waste water
sample bottle for collecting composite samples, a
peristaltic sampling pump, two knob control panel (No
programming required) and a rechargeable gel cell
battery. Other options include glass sample bottles,
refrigerated containers, portable ice containers and
more.
Water Quality Sampler Data Recorder
Global Water’s Water Quality Sampler Data Recorder works
with MS Windows software. The Water Quality
Sampler Data Recorder monitors and logs both water
quality value and time of the sample for your records.
Data downloaded from the Water Quality Sampler Data
Recorder can easily be opened in any PC spreadsheet
program for analysis and graphic presentation.
Water Quality Sampler System Specifications
Composite Water Sampler
Sample Size: 15 composite sample sizes from 50ml
to 2 liters plus a Full Bottle discrete setting
(Approximate sizes at 4 foot head)
Operating Temperature: 0° to +70°C
Materials:
Enclosure: Expanded UV protected PVC
Bottle: 2.5 gallon Polyethylene
Pickup Hose: 15' reinforced PVC 1/4" ID
polyethylene flexible tubing section with intake
strainer
Pump Tubing: Norprene 1/4" ID, 7/16” OD
Sample Pump:
Flow Rate: 1000 ml per minute at a 4 foot
head
Type: Peristaltic
Maximum Lift: ~20 feet
Battery: Rechargeable 5 AH Gel Cell
Battery Life: ~1 hour, continuous pumping under
load
Standby: 3 months while still retaining enough
power to run the pump to capacity
Water Quality Sampler System Controller
Sensor Display: 5 digit + decimal place, LCD
Accuracy: 0.1% of full-scale + .005mA + Sensor
Error
Analog Sensor Input: 4-20mA, 0-5V, 0-1V Jumper
Selectable
Input Resolution: 0.005mA or 1.2mV
Sensor Types/Units: Water Level (Feet/Meters),
Temperature (ºF/ºC), pH (no units), Dissolved Oxygen
(%), Turbidity (NTU/ppm), Conductivity (µS), Wind Speed
(MPH/KPH), Wind Direction (º), Soil Moisture (%), Custom
Sensor (any of the above, mA, mV or custom programmed
units)
Sensor Data Range: 0.000 to 60,000 (60000 in the
display with 4 different decimal point positions)
Relay Contacts: (All Models)
Voltage: 30VDC
Current: 5A/30VDC
Max Capacity: 150W
Relay 1, Pulse Output: NPN to Ground,
1.0Kohm pull-up resistor (connected to sampler) (WQS-STD,
WQS-LTS, and WQS-LTU only)
Relay 2, Pulse Output: NPN to Ground,
Open-collector (WQS-STD, WQS-LTS, and WQS-LTU only)
Relay Time Ranges: 1-60,000 seconds (16.7 hours)
Resolution: 1 second increments
Sleep Time Range: 1-240 minutes (4 hours)
Resolution: 1 minute increments
Analog Output: 4mA minimum, 20mA maximum (Sensor
reading)
Resolution: 0.005mA
Power:
WQS-STD, WQS-LTS, and WQS-LTU: independent
12VDC rechargeable battery
60mA DC normal, 100mA maximum
120uA during sleep mode
WQS-INT: uses the WS700 12VDC rechargeable
battery
60mA DC normal, 100mA maximum
120uA during sleep mode
Water Quality Sampler Data Recorder
Memory: Non-volatile flash memory
Power:
WQS-STD, WQS-LTS, and WQS-LTU: independent
12VDC rechargeable battery
WQS-INT: uses the WS700 12VDC rechargeable
battery
Standby Current: 70uA Typical
Logging Current: 5mA Typical + sensor
current
Analog Sensor Inputs: 4-20mA
Resolution: 12-Bit, 4096 Steps
Sensor Warm-up Time: Programmable, 0-60 Sec
WQS-STD and WQS-INT: 6 Input channels + flow
rate + battery voltage monitor
WQS-LTS and WQS-LTU: flow rate + battery
voltage monitor
Digital Inputs:
Maximum Input Voltage: 24VDC
Maximum Frequency: 100Hz
Minimum Pulse Width: 2mS
Maximum Count: 65,535 (16-Bit)
WQS-STD and WQS-INT: Sample Event + 1 input
channel
WQS-LTS and WQS-LTU: 1 input channel
connected to sampler
Sample Now Input: Sample-on-Demand input,
software enabled (WQS-STD and WQS-INT only)
Maximum Input Voltage: 24VDC
Minimum Pulse Width: 2mS
Sample Modes:
Fixed Interval Programmable from 1 Sec. to >1 Year
High Speed 10 Samples per second
Logarithmic Sample Rate (Approximation)
Exception (Log only on deviation from previous
reading)
Storage Capacity:
WQS-STD and WQS-INT: 40,879 Recordings for
all inputs plus time
WQS-LTS and WQS-LTU: 81,759 Recordings for
all inputs plus time stamp
Data Overwrite: Select memory wrap or unwrap
(unwrap will stop logging data once memory is full)
Communication Ports:
WQS-STD and WQS-INT: RS-232 DB9 or USB Type
B
WQS-LTS: RS-232 4-pin circular connector
WQS-LTU: USB Type B
Selectable Baud Rates: 9600, 19200, 28800,
38400, 57600, 115200
Clock: Synchronizes to the time and date of
user's computer
Operating Temperature: Industrial, -40ºC to +85ºC
(Battery may not apply)
Data Logger Software
Compatible with Microsoft's Windows 98, ME, 2000, NT,
and XP
Windows and Excel are trademarks of the Microsoft
Corporation
Tabular Display/Printout
Data in standard spreadsheet format (.CSV)
Programmable alarm start and stop times
Field calibration software and help files included
Mechanical:
WQS-STD: (2 enclosures)
Sampler Enclosure: 22”H X 17"W X 9"D
Water Quality Logger Enclosure:
14.5”Hx10”Wx6”D
Sampler Weight: 20lb
Water Quality Logger Weight: 13.6lb
WQS-LTS and WQS-LTU: (2 enclosures)
Sampler Enclosure: 22”H X 17"W X 9"D
Water Quality Logger Logger Enclosure:
14.5”Hx10”Wx6”D
Sampler Weight: 20lb
Water Quality Logger Weight: 12.6lb
WQS-INT:
Enclosure: 22”H X 17"W X 9"D
Weight: 21.5lb
Water Quality Sampler System Options
WQS-STD Water Quality Sampling System
Includes triggered WS700 composite water sampler,
PC300 process controller, and GL500-7-2 data
recorder. (NOTE: Water quality sensor not
included.) |
|
|
WQS-LTS Water Quality Sampling System Lite
(Serial)
Includes triggered WS700 composite water sampler,
PC300 process controller, and GL500S-2-1 flow data
recorder integrated into process controller.
(NOTE: Water quality sensor not included.) |
|
|
WQS-LTU Water Quality Sampling System Lite (USB)
Includes triggered WS700 composite water sampler,
PC300 process controller, and GL500U-2-1 flow data
recorder integrated into process controller.
(NOTE: Water quality sensor not included.) |
|
|
WQS-INT Integrated Water Quality Sampling System
Includes triggered WS700 composite water sampler
with built in process controller and GL500-7-2 data
recorder. (NOTE: Water quality sensor not
included.) |
|
|
WQS Water Quality Sampling System with WS750
Water Sampler
Includes flow-proportional WS750 water sampler with
process controller and GL500-7-2 flow data
recorder. (NOTE: Water quality sensor not
included.) |
|
|
4-20mA Water Quality Sensors
Choose to sample based on Turbidity, pH, Dissolved
Oxygen, Conductivity, ORP, or Temperature.
|
|
|
Deluxe PDA Package
Handheld download package for Water Quality Sampling
System. Includes PDA, software field cable, and
rugged carrying case. NOTE: This package does not
work with the WQS-LTU system. |
|
 |
|
RELATED
PRODUCTS |
OxiTop® BOD Measurement Instrumentation
BOD measuring instrument for self-check with 6
measuring units, 115 VAC, 50/60 Hz power plug, and
accessories. |
|
|
AD200-1 Voice Alarm Autodialers
Voice alarm autodialers includes one inputs and four
phone/pager numbers. |
|
|
|
WA400-DC Process Controller Level Alarm
|
|
 |
FSS-STD Flow Sampling System
A unique combination of instruments that makes
monitoring, sampling, and recording stormwater or
industrial discharge water flows easy. |
|