Global Water's
WS700R Refrigerated Wastewater Samplers combine all the
features you need to meet a wide variety of water
sampling requirements, including those for stormwater,
industrial discharge, water and wastewater treatment,
waste collection systems, and rivers and streams.
The WS700R Refrigerated Wastewater Sampler's state of
the art water sampler controller gives you complete
control over your water sampling process. With the
water sample size control, you can take individual
time-weighted composite samples or full-bottle discrete
grab samples in a 2 gallon sample bottle. The water
sample interval control allows you set the time between
individual refrigerated composite samples or enable the
external trigger mode for flow proportional sampling. A
start delay timer allows you to start multiple
refrigerated water samplers in the field at the same
time, or to delay drawing a water sample after a
triggering event so that your water sample better
represents the water source. An automatic 15 second
backflush cycle clears any debris from the strainer and
empties the water from the hose so the next refrigerated
composite sample is not contaminated.
The WS700R Refrigerated Wastewater Samplers are easy
to set up in the field. The refrigerated wastewater
sampler requires two 120 V outlets to power the
peristaltic pump and refrigerator. The refrigerated
wastewater samplers are relatively small and can be
easily hidden or protected inside of a fiberglass
enclosure.
The WS700R Refrigerated Wastewater Samplers come with
a 2.5-gallon polyethylene sample bottle for collecting
refrigerated composite samples, a peristaltic sampling
pump, a circuit board controller, and a rechargeable gel
cell battery. Also provided is a sample pickup hose and
a battery charger. Everything you need is provided for
a successful wastewater management or environmental
monitoring program.
Overflow Protection
The refrigerated wastewater sampler's sample bottle is
equipped with a float switch that automatically turns
off the peristaltic sampling pump if the water bottle
becomes full.
Sample Size
The user can adjust the refrigerated wastewater
sampler's sample size to one of 15 composite sample
sizes from 50ml to 2 liters plus a full bottle discrete
setting and the refrigerated wastewater sampler's sample
interval to one of 15 time settings from 5 min. to 12
hours plus an external trigger mode setting for flow
proportional sampling.
Flow Proportional Sampling
An external pulse-type flow meter can control the water
sample interval for true flow proportional sampling.
Global Water's Open Channel Flow Monitor has a
flow-proportional output signal for triggering the
WS700R refrigerated wastewater samplers. If you already
have a flow meter but it has a 4-20mA output.
Refrigerated Wastewater Samplers Specifications
Operating Temperature: 0° to +70°C
Size of unit: 27"H X 20"W X 20"D
Weight: 40lb (Shipping Weight 42lb)
Materials:
Enclosure: Expanded UV protected PVC
Bottle: 2.5 gallon Polyethylene
Pickup Hose: 15' reinforced PVC 1/4" ID
polyethylene flexible tubing section with intake
strainer
Pump Tubing: Norprene 1/4" ID, 7/16” OD
Sample Pump:
Flow Rate: 1000 ml per minute at a 4 foot
head
Type: Peristaltic
Maximum Lift: ~20 feet
Power: Internal 12V Rechargable Battery with AC
120 VAC adapter/charger
Standby: 3 months while still retaining
enough power to run the pump to capacity
Start Delay: 16 time settings from 0 to 12 hours
Composite Interval: 15 time settings from 5 min.
to 12 hours plus an External Trigger mode setting
Sample Size: 15 composite sample sizes from 50ml
to 2 liters plus a Full Bottle discrete setting
(Approximate sizes at 4 foot head)
External Trigger Input: 250mS minimum pulse width
Switch closure or 4-24VDC
Pulse Output: 5VDC one-second pulse
1000ohm output impedance
Bottle Switch Input: Switch closure Input
Floating read switch in bottle
Rain and Water Sensors: Optional moisture sensors
or switch closure inputs
Internal Fuse: 10A Slow-Blow
WS700R Refrigerated Wastewater Sampler
Refrigerated samplers for composite samples of
stormwater or industrial discharge flows. |
|
|
|
01-342 Quick Release Pump Head |
|
 |
WSSWK Stormwater Kit
Includes CA0400 Rain Sensor, CA0500 Flow Sensor and
RG333 Auto-drain Rain Gauge. |
|
 |
FN0000
Smart Charger
Maintain constant battery voltage and increase
battery life. |
|
|
|
REPLACEMENT PARTS |
00-010 12V
5AH Rechargable Battery
00-546 Reinforced PVC Pickup Hose
CA0300 Pickup Strainer
CA0400 Rain Sensor
CA0500 Flow Sensor
00-744 Peristaltic Pump Tubing
CD0300 Float Switch
01-283 2.5 Gallon Plastic Bottle
RG333 Auto-Drain Rain Gauge
|
|
RELATED
PRODUCTS |
WS700
Composite/Discrete Water Sampler
Single pump stormwater or wastewater sampler.
|
|
|
WS750
Stormwater/Wastewater Sampler
Dual pump stormwater or wastewater sampler.
|
|
|
|
WS500 10 Gallon Composite Sampler |
|
|
WS700-PCO Portable Cooler Composite Sampler
Mobile sampler with attached cooling unit.
|
|
 |
WS700-IBO Ice Bag Composite Sampler
Portable composite sampler with internal ice bag.
One gallon sample bottle included. |
|
 |
RG750/RG755 4-20mA to Pulse Converter Module
This module is for use with flow monitors that
produce a 4-20mA output. There are two versions
available, one that pulses every 15 minutes at 20mA
(RG750) and one that pulses every 30 minutes at 20mA
(RG755). Please specify the unit conversion that
best suits your application at the time of order.
|
|
|
OxiTop® BOD Measurement Instrumentation
BOD measuring instrument for self-check with 6
measuring units, 115 VAC, 50/60 Hz power plug, and
accessories. |
|
|
AD200-1 Voice Alarm Autodialers
Voice alarm autodialers includes one inputs and four
phone/pager numbers. |
|
|
|
3 FT Long Handled Dipper |
|
|
|
Swing Sampler w/Pole & Bottle |
|
|
|
Sludge Judge, 15 FT |
|
|
GL500-7-2 Multichannel Data Logger
Features 7 analog channels and 2 pulse channels, USB
and serial communication port, and includes software
and cables. Requires an external 12 VDC power
source. |
|
|
GL500-2-1 Datalogger
Specify Serial or USB version when ordering.
Features 2 analog channels and 1 pulse channel.
Includes two internal 9V batteries, Windows-based
Global Water Datalogger Software, and PDA software
for the CE operating system. |
|
|
|
WQ900 Water Pollution Testing Kit |
|
|
FSS-STD Flow Sampling System
A unique combination of instruments that makes
monitoring, sampling, and recording stormwater or
industrial discharge water flows easy. |
|
|
WQS-STD Water Quality Sampling System
A unique combination of instruments that allows for
monitoring, sampling, and recording of water flows
that exceed a water quality parameter such as
turbidity, pH, conductivity, ect. |
|
 |
SIT65 Satellite Internet Telemetry
Replace the datalogger on your composite sampler
with a telemetry system that pages you or alerts you
via text messaging that your sampler took a sample.
|