- Handheld Instrumentation : APW |
|
Impossible to wear out, the APW range of field instruments is
the most reliable and commonly used in France.
Simple, robust, and watertight! That’s the recipe PONSEL has
been applying for 55 years.
|
|
|
|
|
APW-PH :
pHmeter
Range : 0,00 to 14,00 pH.
|
The pHmeter APW-PH is a portable instrument,
watertight and robust. Simple to use, no
microprocessor technology : calibration and setting by
simply turning buttons
(no deadlock during measurements).
Wide choice of pH electrodes, adjustable cable length
from 1 to 10 m. Several accessories : strainer of
protection, roller for cable.
Operate with a 9 V battery. |
|
|
 |
|
|
|
|
APW-PH/T :
pH-Thermometer
Range : 0,00- 14,00 pH. 0,0 - 50,0°C
 |
The pH-Thermometer APW-PH/T is a portable instrument,
watertight and robust. Simple to use, no
microprocessor technology : calibration and setting by
simply turning buttons (no deadlock during
measurements).
Its working is similar to a pHmeter but with an
independent Temperature sensor (PT100).
Temperature Range : 0,1 - 50,0°C +/- 0,1°C,
pH Range : 0,00 -14,00 pH.
Wide choice of pH electrodes, adjustable cable length
from 1 to 10 m. Several accessories : protection belt,
winding drum. |
|
|
 |
|
|
|
|
APW-PH/EH :
pH-ORP meter
Range : pH : 0,00 - 14,00
ORP : - 2000 à + 2000 mV
 |
A
practical combination allowing both pH and ORP
measures. With this bi-parameter portable instrument,
it is possible to have the 2 measurements in the same
time because the 2 probes are connected in parallel.
You don't need to disconnect the pH (or ORP) sensor to
connect our ORP (or pH) sensor.
pH Range : 0,00-14,00 pH.
ORP Range : - 2000 ; + 2 000 mV +/- 1 mV.
|
|
|
 |
|
|
|
|
APW-EH :
ORP meter
The APW-EH PONSEL is the ideal tool for controlling the
processes of nitrification/identification
in aeration basin of waste water treatment plant, the
strength of plating bathes or swimming pool disinfection.
 |
ORP Range : - 2000 ; + 2000 mV.
This portable instrument is watertight, robust and
simple to use.
Operated with a 9 V battery. |
|
|
 |
|
|
|
|
APW-O2T :
Oxygen Meter
Range : 0,0 to 19,9 mg/L
 |
Simple, robust and reliable ! That’s the recipe PONSEL
has applied for over 50 years.
The APW-O2T is the ideal tool for controlling
dissolved oxygen concentration in water or any
liquids.
• Protection: IP 67
• Operating temperatures : – 10°C to +60°C
• Technology : Polarographic electrode - Teflon
membrane
• Measuring range :
- Oxygen : 0.0 – 19.9 mg/l
- temperature : 0.0 to 50.0°C
• Accuracy :
- Oxygen : +/- 0.5% displayed value
- Temp. : +/- 0,1 °C
• Power supply: 1x 9V battery- 2000 hours life
time. |
|
|
 |
|
|
|
|
APW-C4E :
Conductivity meter
Range : 0-200/2 000/ 20 000/200 000 µS/cm
(automatic switching of the range)
4 electrodes
sensor
 |
For monitoring process waters, wastewater treatment
plants, and the quality of drinking waters, surface
and underground waters.
Conductivity Range : 0-200 ; 0-2 000 ; 0-20 000
; 0-200 000 µS/cm.
Standard delivery with a sensor with 4 electrodes (2
platinum and 2 graphite) and with a cable of 3 meters
(up to 30 meters). For cable length over 30 meters,
you must choose the sensor with an integrated
amplifier (max. 110 m). |
|
|
 |
|
|
|
|
|
|
APW-MES
: Suspended Solids Meter
Range : 0 to 20 g/L or 0 to 50 g/L
IR optical sensor
allows a direct
on-line measurement ! (no sampling
needed)
 |
The APW-MES use the principle of optical absorption of
IR light and delivers a direct indication in g/l of
the concentration of particles in suspension in all
types of sludge's up to 50 g/l. It measures the
portion of infrared light transmitted through the
sludge.
Simple calibration in laboratory with a known
concentration of a sludge sample (determinated by a
laboratory analysis) is all what is required to
perform these measurements.
Suspended Solid concentration Range : 0-20 g/l
(MES20) ; 0-50 g/l (MES50). |
|
|
 |
|
|
|
|
|
|
APW-TU
: Turbidity meter
Range : 0,0 to 0,200 / 0 to 2000 NTU
IR sensor
allows a direct
on-line measurement ! (no sampling
needed)
 |
Thanks to its robust sensor, it allows a
direct on-line measurements.
No more need for sampling or dedicated measurement
basin.
You could use this instrument in several applications
: monitoring of underground water, natural water
(river, lake, ...), rapid control on urban or
industrial wastewater treatment plant, ....
• Operating temperatures : – 10°C to +50°C
• Technology : Optical Absorption of Infrared
(880nm)
• Measuring range : 0.0 to 200.0 FTU or 0 to
2000 FTU
• Accuracy : 1% displayed value ± 1 digit.
• Protection IP 67
• Cable : 10 m (up to 100 m available on
request)
• Power supply : 1 x 9V battery |
|
|
 |
|
|
|
|
|
|
APW-VB
: Sludge blanket detector
More user friendly than the Secchi disk, the portable
instrument APW - VB Ponsel, gives you a direct reading of
the sludge percentage :
0 % for clear water
100 % for fully opaque sludge
 |
The sensor uses the principle of optical absorption of
the infrared light. A measurement of 100 % correspond
to a ultra-clear water (without any suspended solid)
and a measurement of 0% to a fully opaque sludge
(concentrated sludge). So it becomes very easy to
locate the interface of sludge blanket.
Range : APW-SB20 : 0-3 g/L ; APW-VB50 : 0-50
g/l.
A
very useful and user-friendly for all the individual
waste water controls that need to be done in all
European countries. Reliable, this handheld instrument
permits to realize easy and quick report. |
|
|
 |
|
|
|