ProtoCessor Protocol Software

FieldServer Technologies is a leader in the development of protocol drivers to enable FieldServers and ProtoCessors to meet the demanding needs of our users needing to convert from one protocol to another. This protocol conversion is necessary in today's industrial marketplace where operators are demanding integration of legacy and proprietary products into modern open protocol networks.

Modbus TCP (Modbus Ethernet) Upgrade for Digi Connect ME Device Servers– Upgrade for any Digi Connect ME Device Server to full native Modbus/TCP protocol support via a simple download of the ProtoCessor Modbus Serial to Ethernet Router firmware

 

Modbus TCP (Modbus Ethernet) Upgrade for Digi Connect MEŽ Device Servers

Upgrade any Digi International's Digi Connect MEŽ Device Server to full native Modbus/TCP protocol support via a simple download of the ProtoCessor Modbus Serial to Ethernet Router firmware.

Benefits

  • Allow other native Modbus/TCP clients such as Ethernet enabled PLCs (Programmable Logic Controllers) and SCADA Systems to communicate directly with your product
  • Allow multiple Modbus/TCP Clients to connect to this Modbus/TCP Server simultaneously
  • Eliminate the need for serial port redirectors on workstations
  • Allow Modbus/TCP OPC Servers to communicate directly with your product
  • Completely avoid timing sensitivities prevalent with serial tunneling approaches.

Features

  • Modbus traffic is cached and routed though the single serial port automatically.
  • The ProtoCessor Modbus Serial to Ethernet Router software is fully qualified under the "Modbus Conformance Testing Program", as tested by the Modbus/TCP Conformance Test Laboratory at the University of Michigan, the official Modbus-IDA.org compliance testing body.
  • The ProtoCessor Architecture provides multiple upgrade paths to other protocols, whether they be BACnet IP, EtherNet/IP (ODVA EIP), LonWorks, Profibus or DeviceNet.

Evaluation Software and Tools Provided

  • Download 36 hour MSER (Modbus Serial to Ethernet Router) evaluation firmware here
  • Download 36 hour Modbus/TCP server evaluation firmware here
  • Follow the download procedure to upgrade your embedded Digi Connect MEŽ to a fully operational 36 hour version of a fully Modbus/TCP compliant Modbus Serial to Ethernet Router.

Additional Support from ProtoCessor

If your product does not currently support Modbus RTU or Modbus ASCII you have a number of options:

  • If it supports a protocol such as Metasys N2 Open then ProtoCessor may have an off-the-shelf protocol conversion solution for you already.
  • You could use the ProtoCessor IO Driver Toolkit to write a driver that would be linked with the Modbus/TCP protocol driver and downloaded to the Digi Connect MEŽ
  • You could request us to write the driver for you.

If your product does not already have a Digi Connect MEŽ Device Server installed, consider designing in a ProtoCessor compliant socket for full protocol support using the full ProtoCessor range of products.

OPC Server for Windows workstation support available

Get the full Modbus/TCP protocol specification from www.modbus.org and selecting the "Modbus Standard Library" link.

The full name of the Modbus/TCP protocol is "MODBUS messaging service over TCP/IP" and comprises of Client, Server and Gateway implementations. ProtoCessors support all three of these. The protocol is sometimes referred to as "Modbus Ethernet", "Modbus over Ethernet" or "Modbus TCP".

Digi Connect ME, NetSilicon and NET+ are registered trademarks of Digi International, Inc. in the United States and other countries worldwide.

 